Difference between revisions of "User talk:Pavels Gurskis"

From NetXMS Wiki
Jump to navigation Jump to search
Line 39: Line 39:
  ifName = SNMPGetValue(snmp,".1.3.6.1.2.1.2.2.1.2." . $1);
  ifName = SNMPGetValue(snmp,".1.3.6.1.2.1.2.2.1.2." . $1);
  return %((ifType==6), $1, ifName);
  return %((ifType==6), $1, ifName);
{instance-name} in "Description" filed will be replaced with 3rd parameter returned from the filter script (ifName in that case).


== Node interface ==
== Node interface ==

Revision as of 11:31, 7 November 2014

Welcome to NetXMS Wiki! We hope you will contribute much and well. You will probably want to read the help pages. Again, welcome and have fun! AlexKirhenshtein (talk) 22:12, 24 April 2014 (EEST)

DCI Parameters

Notes on using particular DCIs

ChildStatus

ChildStatus can be used to check status of child items of the nodes, particularly:

  1. Network Service
  2. Interface

While using ChildStatus to check status of the interface, keep in mind, that depending on the device/vendor object ID of the interface might change between the configuration polls. For Cisco switches there's way to preserve ifIndex for the interfaces using snmp-server ifindex persist command (read more about that on Interface Index (ifIndex) Persistence)

PS: This might require entering command in interface (rather than global) context.

PPS: Not sure if works everywhere... write mib-data might be needed as well

SNMP Instance Discovery

Let's say we want to collect status of all interfaces on a node.

Put OID of interest in "Parameter" field on "General" tab with {instance} suffix (.1.3.6.1.2.1.2.2.1.8.{instance}).

Put something meaningful in "Description" filed on "General" tab, use {instance-name} macro to make this human-readable ("Interface status ({instance-name})").

Go to "Instance Discovery" tab.

Pick "SNMP Walk - Values" as discovery method.

Pick proper base OID as described in Creating SNMP table DCI (.1.3.6.1.2.1.2.2.1.1).

Add instance discovery filter script:

snmp = CreateSNMPTransport($node);
ifName = SNMPGetValue(snmp,".1.3.6.1.2.1.2.2.1.2." . $1);
return %((ifType==6), $1, ifName);

{instance-name} in "Description" filed will be replaced with 3rd parameter returned from the filter script (ifName in that case).

Node interface

Notes on working with node interfaces

Parameters

Required poll count

NetXMS will consider interface down only after given number of unsuccessful polls.

Event Processing Policy

SYS_* Events

Please note, that as part of internal event correlation, no SYS_* events processed from the node after receiving SYS_NODE_DOWN event, until SYS_NODE_NORMAL received from that node. However, custom events processed just fine even after SYS_NODE_DOWN event.

Macros for Event Processing

Note, that different set of macros available for Activation and De-activation of alarms. For example, if you use unique DCI ID for alarm generation (%5), you should use different macro to de-activate this alarm (%3)

NXSL scripting

Referring scripts from Script Library

Calling scripts from Script Library:

myVariable=Name::In::Script::Library/functionName

Event Processing Policy

Calling Script Library scripts from Action in Event Processing Policy:

%[Name::In::Script::Library/functionName]