Name |
Type |
Description
|
comments |
string |
Comments (since 2.0-M5)
|
dataType |
int32 |
Configured data type; possible values are:
0 |
Integer
|
1 |
Unsigned integer
|
2 |
64 bit integer
|
3 |
64 bit unsigned integer
|
4 |
String
|
5 |
Floating point number
|
6 |
Null
|
|
description |
string |
Description
|
errorCount |
uint32 |
Number of consecutive data collection errors
|
id |
uint32 |
Unique DCI identifier
|
instance |
string |
DCI instance (only for single value DCIs)
|
lastPollTime |
int64 |
Time of last DCI poll (either successful or not) as number of seconds since epoch (1 Jan 1970 00:00:00 UTC)
|
name |
string |
Parameter's name
|
origin |
int32 |
Data origin (source); possible values are:
0 |
Internal
|
1 |
NetXMS agent
|
2 |
SNMP agent
|
3 |
Check Point SNMP agent
|
4 |
Push
|
|
status |
int32 |
DCI status; possible values are:
0 |
Active
|
1 |
Disabled
|
2 |
Not supported
|
|
systemTag |
string |
System tag; always empty for user-defined DCIs
|
template |
object |
Template object or NULL if this DCI was not added from template (since 2.1.3)
|
templateId |
int32 |
Template object ID or 0 if this DCI was not added from template (since 2.1.3)
|
templateItemId |
int32 |
Template item ID or 0 if this DCI was not added from template (since 2.1.3)
|
type |
int32 |
DCI type: 1 for single valued, 2 for table
|